Malvern itc-200
http://lifefacility.xmu.edu.cn/instrument/detail-65680.html WebMalvern MicroCal iTC 200 Micro Calorimeter Pred PEAQ This Ad Listing has been archived or disabled. Please see more items from Boston Industries, Inc. MicroscopeGuru or browse through our Calorimeter category to find more products for sale on Labx.
Malvern itc-200
Did you know?
Web工作模式: 恒温和扫描 温度范围: 室温~300℃ 升温速率: 0.001~2℃/min 温度准确度:+/-0.1℃ 温度精度: +/-0.05℃ 热焓准确度:+/-1% 量热精度: +/-0.1% 量热分辨率:0.10 μW 样品池容积:最 大12.5 ml 样品池材质:不锈钢及哈斯合金(Hastelloy C)或定制 实验最 高压力:1000bar 样品池种类:安培瓶池、翻转混合池、膜混合池、流体循环池、液体比 …
WebMicroCal PEAQ-ITC, the most advanced Isothermal Titration Calorimetry system from Malvern Instruments, offers high quality data, ease of use, and exceptional... Web微量量热仪Malvern ITC-200. 仪器分类:分析仪器. 运行状态: 空闲. 所属机构:厦门大学 > 医学与生命科学学部 > 药学院. 使用模式:按时预约 . 规格:ITC-200. 放置位置:330. 收藏 机时预约
WebValidation using absorbance spectroscopy and ¹H NMR. a Inhibition experiment with compound 5 using a Malvern ITC-200 calorimeter. Compound 5 is injected into the cell containing POP and TRH (blue... WebCarrier-Free, Dual-Functional Nanorods Via Self-Assembly Of Pure Drug Molecules For Synergistic Chemo-Photodynamic Therapy
WebThey characterized binding kinetics of five compounds to POP using a Malvern ITC-200 calorimeter. Two of them bind non-covalently to POP, while another three form reversible covalent bonds with the catalytic serine in the POP …
WebElectrophoresis gell casting unit (Mini-PROTEAN Casting Set, Bio-Rad) with an optional gradient adapter (385 Gradient Former, Bio-Rad) Type of equipment: Molecular techniques / Chair: Chair of Biochemistry and Food Chemistry. Department: Department of Food Science and Technology. geology im 19th american artWebIsothermal titration calorimetry (ITC) A MicroCal PEAQ-ITC (Malvern Panalytical) was used. The ACE2-IgG4-Fc was in the cell, ... The protein concentration was 10 µM, the inhibitor concentrations were 150–200 µM. For the titration, we used injections of 1.5 and 1.0 µL for the first and second replicate, respectively. geometry goals and objectives for iepWeb7 apr. 2024 · ITC investigation was done using a VP-ITC calorimeter (Malvern Panalytical) as described in . Purified proteins were dialyzed into a single stock of phosphate-buffered saline, pH 7,4 containing 1 mM Tris (2-carboxyethyl) phosphine hydrochloride (TCEP). All solutions were degassed at room temperature immediately prior to use in the test. geometry and topology impact factorWebMicroCal PEAQ-ITC - How to clean the system - YouTube 0:00 / 2:45 MicroCal PEAQ-ITC - How to clean the system Malvern Panalytical 6.66K subscribers Subscribe 8 … geometry dash suWeb10 jan. 2024 · Here are several best practices for performing traditional binding experiments with the MicroCal PEAQ-ITC, VP-ITC and ITC200 systems.. Sample requirements: By convention, the “Macromolecule” is the biomolecule in the isothermal titration calorimeters (ITC) cell, and the “ligand” is the biomolecule in the ITC syringe. These can be any … geophotobank.comWebDownload brochure. MicroCal ITC isothermal titration calorimeters are used to study a wide range of biomolecular interactions. The applications range from drug design to … geometric shape fishWeb它是一款多功能的、高灵敏的、高性价比的等温滴定量热仪,在众多不同应用领域,都令其他竞争对手望尘莫及。 特点: • 标准体积(1.0 mL)或小体积(190 μL)的量热池可供选择 • 通过主动式固态加热及冷却系统,实现真正的恒温控制 • 高精度注射滴定器实现精确的样品传送 • 独特的拆卸式注射针管可实现快速且可靠的装载和清洗 • 强大的仪器控制软件ITC … geometry from mesh