WebAug 12, 2024 · OK Thanks, assuming a shower temp of 40C and a cold water temp of 20C then by calculation the combi flowrate was 4.7LPM at 60C, boiler output 13.1kw. The boiler will have a minimum flow swith probably set to - 2.5/ 3.0 LPM so possibly a erratic/faulty flow switch or temperature sensor. The boiler output is 14.23kw at 10.2LPM & 40C. WebJan 20, 2011 · The boiler is heating the water, then the water leaving the boiler gets too hot so the boiler shuts down until water leaving the boiler is cool again, and then cycles. One solution is to turn DOWN the required temperature of the water. This will stop the boiler overheating the water. This won't stop it, as the plate is blocked on the system side.
How to increase water pressure in a shower with a combi …
WebFeb 13, 2024 · The shower does go cold but only for a couple of seconds. I've run the shower whilst looking at what the boiler lights display and the shower goes cold more or less when the boiler gets to its top temp and the burner cuts. Then, it re lights and the hot water returns. The other hot taps in the house run fine and don't go cold at all. WebMar 14, 2024 · Inside the cylindrical mixing valve - where the shower hose exits - are 2 back flow preventers. They can fail intermittently or permanently, or with any pattern in between … four-wheel drive snow
Shower Going Hot and Cold Combi Boiler JustBoilers.com
WebApr 7, 2024 · Baxi Trainer Rob takes you through the common causes of reduced hot water temperature at the tap when the customer has a combi boiler. WebCombi boilers are great for reducing energy and space in a home, as there’s no need for a hot and cold-water cylinder and they’re often considered to be the most reliable. They have a high-pressure water supply and can run from just 1 bar pressure – meaning that combi boilers, can be used with many powerful mixer showers, saving ... WebMar 4, 2015 · The boiler holds a head of hot water when you open the tap or shower this hot water is pushed out by the cold mains pressure. The boiler will cut in when the cold mains has dropped the boiler temperature to its switch on point. The result can be a flow of hot water to the tap followed by cold water then hot comes back on again. four-wheel drive top gas mileage suvs